Not a valid Time
This is a required field.
CETCO MX-80 GROUT-30-100 Mesh Bentonite 50LB Bag

CETCO MX-80 GROUT-30-100 Mesh Bentonite 50LB Bag

CETCO COARSE CHIPS-Hole Abandonment Material 2000LB Supersack

CETCO COARSE CHIPS-Hole Abandonment Material 2000LB Supersack

CETCO PUREGOLD MEDIUM CHIPS-Hole Abandonment Material 2000LB Supersack

$273.94
Availability: Pending Availability



SKU
CETCO PUREGOLD MEDIUM CHIPS 2000
Sold By the Supersack

2000LB Supersack - 1 per pallet

PureGold Medium Chip are natural sodium bentonite screened to 1/4 inch (0.64 cm) to 3/8 inch (0.95 cm) in size. PureGold Medium Chips are certified to NSF/ANSI Standard 60, Drinking Water Treatment Chemicals - Health Effects.

 

Recommended Use:

Sealing shallow boreholes and seismic shot holes; decommissioning wells; providing an interface between gravel pack and bentonite or cement grout.

 

CHARACTERISTICS:

• Chemically stable. Results from TCLP Priority Pollutants analysis are below RCRA limits for hazardous constituents

• Prevent infiltration of surface contamination

• Provide a high-solids bentonite seal

• Provide a permanent, flexible seal

 

Mixing and Application:

Because chips may develop fines during transporting and handling, bagged material should be screens of fines before placement. Pour chips slowly downhole to prevent bridging or binding In unsaturated conditions, water should be added at 2ft intervals to ensure adequate hydration.

More Information
Size 2,000 lb SUPERSACK
Weight 2075.000000
Product Type Bentonite
New Yes
Description Sold By the Supersack

2000LB Supersack - 1 per pallet

PureGold Medium Chip are natural sodium bentonite screened to 1/4 inch (0.64 cm) to 3/8 inch (0.95 cm) in size. PureGold Medium Chips are certified to NSF/ANSI Standard 60, Drinking Water Treatment Chemicals - Health Effects.

 

Recommended Use:

Sealing shallow boreholes and seismic shot holes; decommissioning wells; providing an interface between gravel pack and bentonite or cement grout.

 

CHARACTERISTICS:

• Chemically stable. Results from TCLP Priority Pollutants analysis are below RCRA limits for hazardous constituents

• Prevent infiltration of surface contamination

• Provide a high-solids bentonite seal

• Provide a permanent, flexible seal

 

Mixing and Application:

Because chips may develop fines during transporting and handling, bagged material should be screens of fines before placement. Pour chips slowly downhole to prevent bridging or binding In unsaturated conditions, water should be added at 2ft intervals to ensure adequate hydration.